High Temperature Flow Meter For Asphalt Mixing

  • Asphalt /bitumen flow measurement by Coriolis mass flow …

    Although the bitumen temperature is very high, the viscosity is still large, and the medium contains a small amount of solid particulate impurities. Conventional liquid flow meters are difficult to meet their bitumen flow measurement requirements. However in-line Coriolis flow meter is a perfect choice for the asphalt /bitumen flow measurement.

    Get Price

  • High Temperature Flow Meter Manufacturer Supplier

    Lake’s High Temperature Flow Meters enable flow monitoring of barrel heating fluids, thermal transfer fluids such as Syltherm® coolant flows, hydraulic circuits, and sub-circuits. Select from aluminum, brass, or stainless steel design for media compatibility requirements. High temperature flow meters are available for air, water, and oil ...

    Get Price

  • A better way to measure bitumen - Siemens Global …

    measure volumetric flow and they can also be prone to inaccuracies and drift over time. The real alternative is a SITRANS FC430 Coriolis flowmeter – a superior solution involving a compact, reliable, accurate and safe mass flowmeter that’s easy to install and simple to operate. asphalt and other materials are increas-ingly being used.

    Get Price

  • High-temperature flow meter - All industrial manufacturers ...

    Find your high-temperature flow meter easily amongst the 42 products from the leading brands (YOKOGAWA Europe, ENDRESS HAUSER, KROHNE, ...) on DirectIndustry, the industry specialist for your professional purchases.

    Get Price

  • Asphalt Plant Equipment - ceienterprises

    The controls also include an asphalt high temperature backup controller and alarm switches for low and high asphalt levels. An asphalt level float gauge is also included. Options. Available options for direct-fired asphalt tanks include 300 gallon fuel tank; Asphalt metering system; 4' rear frame extension with cable rack & step; 6-inch insulation

    Get Price

  • Laboratory Mixing and Compaction Temperatures for …

    – Mixing temperature • can best be defined as the temperature at which the aggregate can be sufficiently and uniformly coated. • As with the lab temperatures, the mixing temperature should not exceed 177°C (350°F). – Compaction temperature • usually in the range of 135-155°C (275-310°F)

    Get Price

  • Why Tracking Temperatures is Key to Successful Asphalt …

    Why Tracking Temperatures is Key to Successful Asphalt Paving. The temperature of the mix on the base after it has passed through the laydown machine – not the mix or manufacturing temperature -- is the most important factor in determining the available time for compaction. Hot mix asphalt pavement arrives at a project at temperatures between 275°F...

    Get Price

  • Asphalt /bitumen flow measurement by Coriolis mass flow meter

    Asphalt flow measurement is always a technical problem because of the high viscosity and poor fluidity. The operation temperature of the pipeline liquid asphalt is usually around 200 ° C. Although the temperature is very high, the viscosity is still large, and the medium contains a small amount of solid part

    Get Price

  • Asphalt-Rubber Systems - CEI Enterprises

    Portable Mixing Unit. Then, the GTR is blended with virgin asphalt by a high shear mixer running at a speed of 3400 rpm. As the materials are mixed, they are pumped to the portable holding tank. During the mixing process, fresh materials are continuously fed into the chamber until the required volume of material has been mixed.

    Get Price

  • Mixing shall be done with a twin shaft pug mill-type …

    Paving grade asphalts shall be added to the aggregates, in both batch and drier-drum plants, at a temperature between 285EF (140EC) and 350EF (177EC). The temperature of the aggregates at the time of adding the asphalt cement shall not be less than 265 EF (130EC), nor more than 325 EF (163EC).

    Get Price

  • Asphalt Concrete Plant Inspection - dot.ca.gov

    ingredients are combined at high temperature near 400°F and a high shear mixer blends the rubber and asphalt together. The asphalt binder and the crumb rubber are allowed to react then loaded into a tanker truck and shipped to the asphalt plant. The terminal

    Get Price

  • Metering bearcatpumps

    Pump Pulsations and Cavitation. If a pump has two gears, each with six teeth, the pump will create 12 pulses per revolution. • Example a pump rotating at 400 RPM is creating 4800 pulses per minute. This frequency is high enough that it would not affect many traditional methods …

    Get Price

  • High Temp Flow Switch - sierrainstruments

    Designed for medium and high temperature applications. Medium Temperature to 300C (572F) ; High temperature to 485C (850F). Optional remote electronics for use in medium and Hi T environments. Switches on a flow/no flow condition in both gases and liquids. Flow Switch range of 0.01 to 5 fps in liquids and 0.1 to 500 fps gases.

    Get Price

  • What Flowmeter Will Work Best for Your Application? from ...

    The meters track mass flow and offer a very high turn-down ratio. Yet initial expense is high, clogging can occur, and meters are larger in overall size. Coriolis flowmeters offer true mass flow measurement through two designs a single tube or two parallel tubes.

    Get Price

  • High Temperature Flowmeters - ThomasNet

    Distributor of high temperature flow meters such as gas meters. Types of meters include rotary gas, turbine gas, diaphragm & refurbished gas meters for gas measurement. Meters are available with capacity ranging from Pilot to over 140,000 scfh & maximum operating pressure ranging from …

    Get Price

  • High Temperature Water Flow Meters Products & …

    Four events can trigger an emergency shutdown 1.) low cooling water flow alarm from the turbine flow meter , 2.) high temperature alarm before the BPR, 3.) high pressure alarm in the WCHB reactor, or 4.) operator initiated shutdown via a “kill” switch.

    Get Price

  • High Temperature Coriolis - emerson

    High Temperature Coriolis Precise, reliable measurement for high temperature applications. Best-in-Class High Temperature Coriolis – only from Micro Motion®. With close to twenty years experience specifically in high temperature applications, you can count on Emerson’s Micro Motion ® Coriolis meters to handle the heat.

    Get Price

  • Effects of Temperature in Mechanical Properties of …

    Effects of Temperature in Mechanical Properties of Stone Mastic Asphalt ... plastic flow and increase shear modulus at high temperature, thus significantly improves the ... is a gap graded hot mix ...

    Get Price

  • Hot Mix Asphalts 101 - state.nj.us

    temperature • High stiffness at high in-service temperature • Low stiffness at low in-service ... • Thermosetting materials flow under stress when heated but, once cooled, cannot be re-softened by heat. ... crumb rubber to hot mix asphalt (called dry process) or the asphalt binder (called wet process) to …

    Get Price

  • Coriolis Flow Measurement Flow Measurement Siemens

    Designed for high-accuracy mass flow measurement with a low cost of ownership, SITRANS F C Coriolis flowmeters are ideal for demanding liquid and gas processes in every industry - from the smallest dose of chemicals to the massive quanities of bunker fuel pumped into a cargo ship.

    Get Price